Free Global Shipping Starts at $50
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance
Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance

Agilent SH-100 Dry Scroll Vacuum Pump Tip Seal Replacement Kit - Gray Repair Parts for Scientific Labs & RD Centers | Laboratory Pump Accessories | 1-Piece Alternative Solution for Vacuum System Maintenance

$109.45 $199 -45% OFF

Free shipping on all orders over $50

7-15 days international

16 people viewing this product right now!

30-day free returns

Secure checkout

20486198

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

HONSVA Tip Seal Replacement Kit for Agilent Dry Scroll Vacuum Pump The Agilent scroll dry pumps require routine maintenance and simple infrequently seal replacement during pump’s service life. The tip seal is a critical service part for the vacuum pump. The tip seal is wearable part and require occasional replacement to prevent pump seizures and to keep the pump at optimal operating. Our tip seals are exclusively formulated by professional RD teams and thousands of on-site testings and practice, have been widely used and recognized by scientific labs and instruments, research centers worldwide, can reliably serve scroll vacuum pump and reduce down-time and costly service expense. The alternative option is lower cost than genuine one, but the same performance as that. Package: including tip seal*1 pieces. Applied to Agilent scroll pump: Triscroll 300/600/620/800. Premium PTFE Raw Material Advantages of PTFE seals are: low wearhigh extrusion resistancehigh temperature resistancegood chemical resistancecompactoperating pressure of up to 800 bar, surface speed up to 5 m/s. Exclusive Formula Developed Using our years of high-quality manufacturing technology, coupled with an in-depth undeerstanding of the seal mechanism for vacuum pump, our R&D team had successfully compoud and exclusively formulated this tip seal for brand scroll vacuum pump models available on market. Easy and Fast to Replace The tip seal replacement for IDP series is easier and faster than any other models. Just prepare some simple tools (such as flat head screw driver, Allen wrenches, lint-free wipes), together with this tip seal set ( 1 pcs) . See how simple to replace the tip seal at official website. Trust Us as your Lab Vacuum Pump Professional Replacement or Maintaining Solution! Performance Same as Genuine OEM Replacement Kit! Tip seal replacement are highly recommended when vacuum pump base pressure is up to an unacceptably high level for your application. Easy to Deal with the Replace Process! Attention and Tips: Never power your pump on when it is dissembled, and always use proper personal protective equipment while replacing.Run pump for about 40 hours (highly recommended) after finishing the replacement for optimum performance, as pumps with newly installed tip seals may require several days of operation to seat properly. Explore more tip seal for other models or brands... Tip Seal for Agilent Triscroll Series Tip Seal for Leybold Tip Seal for Edwards nXDI Series Tip Seal for Ulvac DVS Series Tip Seal for Iwa ISP Series Tip Seal for Busch Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Add to Cart Customer Reviews — — 2.5 out of 5 stars 3 — 5.0 out of 5 stars 1 — Price $289.90$289.90 $249.00$249.00 $219.90$219.90 $399.90$399.90 $255.00$255.00 $259.00$259.00 Package included *pcs 1 2 2 4 2 4 Color Dark Grey Yellow Yellow Black Dark Grey Dark Grey Materiel PTFE-Teflon, Black Foam-back PTFE-Teflon PTFE-Teflon PTFE-Teflon PTFE-Teflon, white Foam Back PTFE-Teflon Applied Pump Brand for Agilent for Leybold for Edwards for Ulvac for IWATA for Busch Be Compatible with Triscroll Series: TS-300/600/620/800 SCROLLVAC 15 Plus, 18 Plus nXDS & XDS Series: XDS5/10/35i/46i; nXDS6i/10i/15i/20i DVS Series: DVS-631/DVS-321 ISP Series: ISP-90/250/500/502/503 FO 0009 A/15A/18A/35A

Features

    Cost-down for Routine Maintenance The tip seal alternative is less costly compared with genuine version,but a perfect replacement substitute for Agilent SH series dry scroll pump. Dry Scroll Vacuum pumps require routine maintenance and simple tip seal replacement to ensure the pump running under optimizing working condition; the tip seal is wearable parts, which require occasional purchasing. This service set is inexpensive while with the same features and performance.

    Reliable and Proven Working Performance Quietly running, low noise vibration, fine friction coefficient, fitting the scroll groove seamlessly, preventing air or gas leaking and pump down-time. The tip seal set has been tested and used by scientific labs, universities, research institutions worldwide, helping them get the optimal sealing performance for vacuum pump, being applied to the four oil-free Agilent SH series, namely SH 100/SH 110/SH112.

    PTFE material for Long Service Interval the foam backed tip seal is based on selected and imported raw material Teflon (PTFE), developed by professional R&D team, exclusively formulated, precisely testing and on-site practice, there is no worry about the tip seal durability, more than 1 years performing lifetime.

    Easy to install and long guarantee The quick and simple SH series tip seal replacement procedure just takes about 15 minutes by professional and experienced personal. Please follow the Quick Guide Manual or video on official website properly using proper personal protective equipment while working. Twelve months guarantee, contact us for any inquiry or problem at any time.

    What you get The tips seal is gray, light weight-50 gram/2.01 ounce. The package comes with a white box, including 1 piece of tip seal, long enough for the 2 scroll tip grooves, namely on the stationary and orbiting scroll.